GEM High-Purity Germanium (HPGe) Coaxial Detectors
(in PopTop Capsule) |
|
For computer-based analysis of complex spectra
requiring the best in resolution, peak-to-Compton ratio, peak shape, and
efficiency: |
- Large stocklist at all times
- Efficiencies to 150%, higher on request
- New "Application-Tuned" PROFILE Series available
- PopTop flexibility
- Excellent energy resolution
- Excellent peak symmetry
- Automatic high-voltage shutdown protects
preamplifier input FET
- Indicator warns of excessive counting rate
- PLUS preamplifier option for ultra-high-rate
applications
|
|
GEM Series HPGe detectors are manufactured with
ORTEC’s own HPGe (see Part A, Section A1.) and represent the state of
the art in "conventional", i.e., outer contact Li diffusion and inner
contact ion-implanted HPGe coaxial detectors (Fig.). Because of the
superior quality of ORTEC’s HPGe material, GEM detectors feature
the best available energy resolution, peak-to-Compton ratios, and peak
symmetry ratios at 1.33 MeV. Note that energy resolution and symmetry
ratios are warranted to two decimal places. |
|
The high degree of symmetry resulting from the
superior material and processes used in manufacturing ORTEC detectors
make them ideal for computer-based analysis where the detector peak
shape is of paramount importance. |
|
ORTEC is renowned for delivering detectors with
measured specifications substantially better than the warranted
values. |
|
The geometrical features of the GEM detector
that result in such excellent peak shape are: (1) by far the world’s
best germanium crystals, (2) deep holes used for making the central
contact, (3) "bulletized" (rounded) front corners on the detector for
uniform electric field. No one makes detectors as well as ORTEC. |
|
|

Figure. Configurations of Coaxial Germanium Crystals. |
|
|
ORTEC maintains a large stocklist of GEM detectors.
Some of these have "super specifications," that is, a warranted
energy resolution better than the first category GEM specifications. |
|
Unless otherwise specified, each GEM HPGe coaxial
detector is supplied in a PopTop capsule. A complete detector assembly
requires a cryostat and a dewar |
|
Options of Interest |
- PLUS preamplifier option for ultra-high-count-rate
applications
- Non-PopTop low-background versions of the GEM
detector are available
- X-COOLERoption for practical LN2-free cooling ,
SMART-1 "Intelligent" detector option
|
|
Ordering Information |
|
GEM HPGe Coaxial Detector (Non-PopTop or PopTop) |
|
For GEM Detector in PopTop capsule†, add
"P4" to the model no. [e.g., GEM90P4]. FW.02M/FWHM specification is
Typical, all other specifications are warranted. |
|
Model
No. |
Efficiency (%) |
Resolution |
Peak-to-Compton Ratio |
Peak
Shape* |
|
@ 122
keV (keV) |
@ 1.33
MeV (keV) |
FW.1M/
FWHM |
FW.02M/**
FWHM |
|
GEM150 |
150 |
1.30 |
2.3 |
90:1 |
2.0 |
3.1 |
|
GEM140 |
140 |
1.30 |
2.2 |
90:1 |
2.0 |
3.1 |
|
GEM130 |
130 |
1.30 |
2.1 |
90:1 |
2.0 |
3.1 |
|
GEM120 |
120 |
1.30 |
2.1 |
86:1 |
2.0 |
3.1 |
|
GEM110 |
110 |
1.30 |
2.1 |
85:1 |
2.0 |
3.0 |
|
GEM100 |
100 |
1.20 |
2.1 |
83:1 |
2.0 |
3.0 |
|
GEM90 |
90 |
1.20 |
2.0 |
80:1 |
2.0 |
3.0 |
|
GEM80 |
80 |
1.10 |
2.0 |
77:1 |
2.0 |
3.0 |
|
GEM75 |
75 |
1.10 |
2.0 |
77:1 |
2.0 |
3.0 |
|
GEM70 |
70 |
1.00 |
2.0 |
75:1 |
2.0 |
3.0 |
|
GEM65 |
65 |
1.00 |
1.95 |
73:1 |
1.9 |
3.0 |
|
GEM60 |
60 |
1.00 |
1.95 |
70:1 |
1.9 |
3.0 |
|
GEM55 |
55 |
1.00 |
1.90 |
67:1 |
1.9 |
2.8 |
|
GEM50 |
50 |
0.90 |
1.90 |
66:1 |
1.9 |
2.6 |
|
GEM45 |
45 |
0.90 |
1.90 |
64:1 |
1.9 |
2.6 |
|
GEM40 |
40 |
0.87 |
1.85 |
64:1 |
1.9 |
2.6 |
|
GEM35 |
35 |
0.85 |
1.85 |
62:1 |
1.9 |
2.6 |
|
GEM30 |
30 |
0.85 |
1.85 |
60:1 |
1.9 |
2.6 |
|
GEM25 |
25 |
0.82 |
1.85 |
56:1 |
1.9 |
2.6 |
|
GEM20 |
20 |
0.82 |
1.80 |
52:1 |
1.9 |
2.6 |
|
GEM15 |
15 |
0.82 |
1.80 |
46:1 |
1.9 |
2.6 |
|
GEM10 |
10 |
0.80 |
1.75 |
41:1 |
1.9 |
2.6 |
|
Options |
|
|
|
|
|
|
|
-PLUS |
Ultra-high-count-rate Preamplifier, add "-PLUS" to
the model number [e.g., GEM10P4-PLUS for PopTop or GEM10-PLUS for Non-PopTop] |
|
SMART-1-P |
SMART-1 detector option for positive bias detector.
To order, add SMART-1-P as a separate line item. |
|
-PLB |
Reduced background PopTop Capsule, add "-PLB" to the
model number [e.g., GEM10P4-PLB] |
|
†All GEM PopTop detector capsules include sealed
detector element, preamplifier, and high-voltage filter. Useful energy
ranges, from 40 keV to 10 MeV. |
|
*FWHM = Full Width at Half Maximum; FW.1M = Full
Width at One-Tenth Maximum; FW.02M = Full Width at One-Fiftieth Maximum;
total system resolution for a source at 1000 counts/s measured in
accordance with ANSI/IEEE Std. 325-1996, using ORTEC standard electronics. |
|
**Typical Value. |
|
NOTE: For those familiar with HPGe detector
specifications, you will notice that ORTEC now offers ONLY "first
category" detector specifications. Recent process improvements now make
this possible. |
|